Ideal set of 2273 all in one handy case, you will receive the following
Hand Carry Case
2273-202 * 40
2273-203 * 50
2273-204 * 50
2273-205 * 40
2273-208 * 20
Tech Specs
2273-202
Total number of connection points | 2 | |
Total number of potentials | 1 | |
Pollution degree (1) | 2 | |
Rated voltage EN (1) [V] | 450 | V |
Rated surge voltage (1) [kV] | 4 | kV |
Nominal current [A] | 24 | A |
Connection technology (1) | PUSH WIRE® | |
Number of connection points (1) | 2 | |
Solid sizes 1 | 0.5 … 2.5 mm² / 18 … 14 AWG | |
Strip length 1 | 11 mm / 0.43 in | |
Strip length from 1 [mm] | 11 | mm |
Strip length up to (1) [mm] | 11 | mm |
Type of wiring | Side-entry wiring | |
Fire load [MJ] | 0.014 | MJ |
Weight [g] | 0.713 | g |
Width | 10 mm / 0.394 in | |
Height | 5.8 mm / 0.228 in | |
Length | 16.7 mm / 0.657 in | |
Safety information 1 | In grounded power lines |
2273-203
Total number of connection points | 3 | |
Total number of potentials | 1 | |
Pollution degree (1) | 2 | |
Rated voltage EN (1) [V] | 450 | V |
Rated surge voltage (1) [kV] | 4 | kV |
Nominal current [A] | 24 | A |
Connection technology (1) | PUSH WIRE® | |
Number of connection points (1) | 3 | |
Solid sizes 1 | 0.5 … 2.5 mm² / 18 … 14 AWG | |
Strip length 1 | 11 mm / 0.43 in | |
Strip length from 1 [mm] | 11 | mm |
Strip length up to (1) [mm] | 11 | mm |
Type of wiring | Side-entry wiring | |
Fire load [MJ] | 0.019 | MJ |
Weight [g] | 1.017 | g |
Width | 14 mm / 0.551 in | |
Height | 5.8 mm / 0.228 in | |
Length | 16.7 mm / 0.657 in | |
Safety information 1 | In grounded power lines |
2273-204
Total number of connection points | 4 | |
Total number of potentials | 1 | |
Color | gray | |
Pollution degree (1) | 2 | |
Rated voltage EN (1) [V] | 450 | V |
Rated surge voltage (1) [kV] | 4 | kV |
Nominal current [A] | 24 | A |
Connection technology (1) | PUSH WIRE® | |
Number of connection points (1) | 4 | |
Solid sizes 1 | 0.5 … 2.5 mm² / 18 … 14 AWG | |
Strip length 1 | 11 mm / 0.43 in | |
Strip length from 1 [mm] | 11 | mm |
Strip length up to (1) [mm] | 11 | mm |
Type of wiring | Side-entry wiring | |
Fire load [MJ] | 0.025 | MJ |
Weight [g] | 1.3 | g |
Width | 18 mm / 0.709 in | |
Height | 5.8 mm / 0.228 in | |
Length | 16.7 mm / 0.657 in | |
Safety information 1 | In grounded power lines |
2273-205
Total number of connection points | 5 | |
Total number of potentials | 1 | |
Color | transparent | |
Pollution degree (1) | 2 | |
Rated voltage EN (1) [V] | 450 | V |
Rated surge voltage (1) [kV] | 4 | kV |
Nominal current [A] | 24 | A |
Connection technology (1) | PUSH WIRE® | |
Number of connection points (1) | 5 | |
Solid sizes 1 | 0.5 … 2.5 mm² / 18 … 14 AWG | |
Strip length 1 | 11 mm / 0.43 in | |
Strip length from 1 [mm] | 11 | mm |
Strip length up to (1) [mm] | 11 | mm |
Type of wiring | Side-entry wiring | |
Fire load [MJ] | 0.03 | MJ |
Weight [g] | 1.581 | g |
Width | 22 mm / 0.866 in | |
Height | 5.8 mm / 0.228 in | |
Length | 16.7 mm / 0.657 in | |
Safety information 1 | In grounded power lines |
2273-208
Total number of connection points | 8 | |
Total number of potentials | 1 | |
Color | transparent | |
Pollution degree (1) | 2 | |
Rated voltage EN (1) [V] | 450 | V |
Rated surge voltage (1) [kV] | 4 | kV |
Nominal current [A] | 24 | A |
Connection technology (1) | PUSH WIRE® | |
Number of connection points (1) | 8 | |
Solid sizes 1 | 0.5 … 2.5 mm² / 18 … 14 AWG | |
Strip length 1 | 11 mm / 0.43 in | |
Strip length from 1 [mm] | 11 | mm |
Strip length up to (1) [mm] | 11 | mm |
Type of wiring | Side-entry wiring | |
Fire load [MJ] | 0.039 | MJ |
Weight [g] | 2.17 | g |
Width | 18 mm / 0.709 in | |
Height | 10.4 mm / 0.409 in | |
Length | 16.7 mm / 0.657 in | |
Safety information 1 | In grounded power lines |
This Product will be supplied in a carry case box
FAQs
Should WAGO connectors be used in an enclosure?
In order to comply with the requirements of the 16th Edition of the IEE Wiring Regulations/BS7671, all connectors should be used in a suitable enclosure of material complying with the relevant glow-wire test requirements of BS 458-2.1. (Fire hazard testing for electrotechnical products). This will provide
mechanical protection for the connectors as well as protection against dust, damp and accidental damage. Although WAGO connectors are IP20 (finger touch) with Polyamide 6.6 housing for strength and durability.
Do they need to be fixed in an enclosure?
The junction box connectors do not have to be fixed down in the housing provided that the cables are secured on their way into the box. However, fixing provides a more secure and professional looking finish.
Does there need to be strain relief on the cable?
Yes, there should be strain relief on the cable. This could be the cable clipped outside the enclosure or cable glands within the enclosure to prevent the cables being pulled out of the connectors.
I'm used to screw connections - how secure is your clamping system?
The WAGO Cage Clamp? and PushWire clamping systems guarantee gastight, maintenance-free connections every time. Our connectors incorporating these proven technologies have been used in industrial and building services applications worldwide. The company's reputation is built on the high quality and proven performance of our products. For installers, this ensures complete peace of mind.
How do I release the conductor from the terminal?
All WAGO connectors are re-usable. PushWire conductors are removed by pulling the conductor and twisting the connector. Cage Clamp? connections are released by using a screwdriver or pushbutton/lever operation.
Do your connectors comply with British Standards?
BSI recognise and harmonise with IEC 60947, 60998 and 60999. These are European standards which relate to terminal blocks and connectors. All WAGO products conform to these standards and other international requirements.
What other standards do your connectors comply with?
WAGO sells its products worldwide and is therefore in constant contact with testing and approvals houses around the globe.
There's a small cavity in a ceiling, wall or floor. Can a terminal block be fitted without the need for an additional back box?
Yes. When installing backless equipment, such as a domestic style luminaire, it is possible for the enclosure to be formed or completed with building material considered to be non-combustible when tested to BS 476-4. (Fire tests on building materials and structures. Non-combustibility tests for materials). Where there is any doubt that the building material does not meet this standard, the electrical connections should be shielded from the fabric of the building by a suitable electrical back-box.