Welcome visitor, please login or create an account.

Infrared remote Relay Control Module 5V 8-Channel High Low Level Trigger

Manufacturer: Generic
Product Code: INFRARED-REMOTE-8WAY
Availability: In Stock
FastFind: 242367
£11.99

Description

FEATURES
  •   Dual Trigger design, using special two-way IC driver design
  •   Anti-jamming capability, using freewheeling diode protection
  •   Part of the relay contacts using double-sided bold wiring to endure a larger current through
  •   5.08mm high quality input and output terminals are used, and can be wired to a microcontroller for further control
  •   Inputs can be set high and low trigger, giving more flexible control
  •   Each relay has a LED to show the status for of the relay
  •   With 4 fixing holes to aid mounting the device.

Specifications:
1. Dimensions: 133 (L) * 55 (W) * 19 (H) mm;
2. The relay contact capacity: AC250V 10A DC30V 10A;

Product wired as follows:
1. VCC 5v: input supply power supply terminal
2. GND: input power is grounded terminal
3. Relay 1 to 8 trigger signal input is level is set by onboard jumper

Some of the PCB is labeled in Chinese. So I will help describe the connections and jumpers.

With the Board facing you, i.e. the infra-red sensor at the front.
1) There are 10 blue screw terminals from Left to Right they are
     VCC 5v
     GND
     CTR8
     CTR7
    
CTR6
     CTR5

      CTR4
     CTR3
    
CTR2
     CTR1
 
You need to apply VCC 5v+ and GND to power the board.

External Trigger to Energise the Relay
Behind the 10 blue terminals there are 8 * 3pin jumper selection one for each relay. In the default position with the jumper across pin 1 and 2, while the external trigger on CTR8 to CTR1 is HIGH the relay will be energised.
By placing the jumper across pins 2 and 3, then while the external trigger on CTR8 to CTR1 is LOW the relay will be energised. So by selecting the position of the jumper you can select the external trigger level High or Low to energise the relay.

Please note: For the relay to operate using the remote control function, the jumper must be left in the default position 1 and 2.

Behind the relays is a further row of blue screw terminals, 3 for each relay.
From Left to Right
NC, Com, NO for Relay 8

NC, Com, NO for Relay 7
NC, Com, NO for Relay 6
NC, Com, NO for Relay 5
NC, Com, NO for Relay 4
NC, Com, NO for Relay 3

NC, Com, NO for Relay 2
NC, Com, NO for Relay 1


(NC is Normally Closed contact, Com is Common and NO is Normally open contact)

Remote Control Function.

Please ensure the jumper selection is in the default position 1 and 2
Pressing a number between 1 to 8 will energise the corresponding relay and REMAIN energised. Pressing the number between 1 to 8 again will de-energise the corresponding relay.

Press the number 0 will de-energise all the relays


Press the number 9 will energise all the relays

THE INFRA-RED SENSOR POINTS DOWN SLIGHTLY, DO NOT ATTEMPT TO STRAIGHTEN THIS, AS YOU WILL BREAK THE LEGS.

Powered by Flexibasket